# Compact junction cell (chip_11m) Not a full chip but the unit cell of a junction test array: one trilayer junction in a 12 × 12 µm exposure window, made of a straight finger, a bent finger and two small HSQ boxes. The cell is meant to be repeated across a wafer to measure junction resistance against size. The script also defines two probe pads but never draws them. It comes from Quantcore's QWri script `chip_11m_TestJJ16x_pads.py` (internal; chip_11f places the same cell). The rebuild puts one 0.5 × 0.6 µm junction on a probe-pad pair in the middle of an otherwise empty PDK die (device ID `CHIP11M`), valued at 45 kΩ on the PDK junction rule. Build it to see the smallest repeatable unit of the junction chips. ```{image} ../../images/designs/legacy/chip_11m_testjj16x_pads.png :alt: The whole chip_11m_testjj16x_pads die with one pad pair at the centre :width: 100% ``` ## At a glance | | | |---|---| | Notebook | `examples/designs/legacy/chip_11m_testjj16x_pads.ipynb` (design JSON `chip_11m_testjj16x_pads.json`) | | Source | Quantcore legacy QWri script `components/python/chip_11m_TestJJ16x_pads.py` (internal) | | Chip | 7.5 × 7.5 mm Quantcore die, sapphire | | On the chip | 1 `ProbePadPair` with 1 `Trilayer Junction Compact` (0.5 × 0.6 µm) | | Builds today | yes, rebuilt from its JSON on 2026-11-19 in 0.9 s (the notebook itself was not re-run) | ## Pictures ```{figure} ../../images/designs/legacy/chip_11m_testjj16x_pads_legacy_1000.png :alt: Legacy chip_11m junction cell :width: 45% The original legacy layout (render of the legacy GDS), a close view of the junction at the centre. ``` ```{figure} ../../images/designs/legacy/chip_11m_testjj16x_pads.png :alt: Rebuilt chip_11m_testjj16x_pads :width: 100% The rebuild: one probe-pad pair at the die centre. ``` ```{figure} ../../images/designs/legacy/chip_11m_testjj16x_pads_jjclose.png :alt: Zoom on the junction :width: 45% The junction window at the centre (a 40 µm view), where the two fingers meet. ``` ## LOM estimates The notebook has no saved LOM output. The chip has no qubit or resonator, so its LOM netlist is empty. ## Build spec The rest of this page is the detailed spec the notebook was built from: every component, the changes made while rebuilding, and the notes. Source: `components/python/chip_11m_TestJJ16x_pads.py` (`create_testPad(size, secondFinger)`, writes `chip_11m_jnc_.gds` with one cell `JX_500`; `__main__` calls `create_testPad(2.5, 0.6)`). Legacy QWri library, Quantcore internal. Notebook `examples/designs/legacy/chip_11m_testjj16x_pads.ipynb`. ### Changes made in the rebuild - Junctions: `JX` (0.5 × 0.6 µm) on the PDK junction rule (Nb trilayer, Δ = 1.4 meV, I_c·R_n = πΔ/2e = 2.20 mV, R_n 40–50 kΩ, qubits 4–8 GHz; PDK process `get_pdk().junction`: R_n·A 13.5 kΩ·µm², C_J 50 fF/µm², both assumed by the PDK): 45 kΩ; chip_11f's JX_500 (0.2 × 0.6 µm) 112.5 kΩ. - The notebook's JSON was rebuilt from its layout cell. The notebook has not been re-run, so its outputs are cleared and its PNGs may be out of date. What it is: the unit cell of a junction test array, not a full chip ("this is the unit cell which will be scaled"; "creates the junction in-house, without the junction_creator"). One trilayer junction in a 12 × 12 µm exposure window: a straight finger (`JJ_finger Top`, mirrored, 1.2 µm lead) on 2/0, a bent finger (`JJ_finger Bottom`, 1.6 µm lead) on 4/0, two 0.2 µm HSQ boxes on 500/0, and a triangular notch cut from each finger window where its lead meets the window edge. The script defines two 500 × 400 µm probe pads and a 600 × 1000 µm window but never inserts them (only the junction is drawn); the pads it is meant for are patterned elsewhere (not in the library). `chip_11f_JJplacer.py` places this cell, built with `create_testPad(1.0, 0.6)`, at external coordinates (see `chip_11f_jjplacer.md`). The script declares the gradient layers 52/53/54 but draws none. Builds: yes. `TrilayerJunctionCompact` (the port of `JX_500`, golden test `test_trilayer_junction_compact[1.0-0.6 / 2.5-0.6]`). ### Components (legacy frame) | instance | legacy cell → catalog ref | params | at | notes | |---|---|---|---|---| | JX | `create_testPad(2.5, 0.6)` → cell `JX_500` → `TrilayerJunctionCompact(finger_width=0.5, second_finger_width=0.6)` | straight finger `0.2·size` = 0.5 µm (no bias), bent finger 0.6 µm, window 12 × 12 µm, HSQ 0.2 µm wide with 45 nm overlap | legacy window centre (0, 0) → Designer (3750, 3750); the cell's origin is its window's lower edge, so `at = (3750, 3744)` | the `__main__` call; chip_11f's variant is size 1.0 (0.2 µm) | No die in the source (it writes the bare cell). Rebuilt on the PDK v2 die frame (the Quantcore chips), the cell at the die centre, with the device ID `CHIP11M`. ### Routes, test pads, LOM No routes, no pads. LOM: `TrilayerJunctionCompact`'s model is one JJ branch `J_JX` from `JX.j` (port `common`, the lead that lands on the separately patterned pad) to ground; `common` is listed as unconnected (nothing in this source attaches to it). Junction values from the area (0.5 × 0.6 µm², assumed Jc: to be confirmed). "LOM simulation" = the junction table (this cell, and the size-1.0 variant chip_11f places). No sim groups, no FEM jobs. ### Keep-outs None: a 12 µm cell at the die centre.