quantcore_circuits.lom.calibration

Component LOM calibration: knob → element value, per component and PDK (no FEM needed to get a first LOM).

Each entry is a power law v = v0 (k/k0)^p anchored at a reference simulation of the component geometry, the same form the co-design surrogate refines (quantcore_circuits.codesign). Values are fF. The reference geometry is the example Xmon (arm width 25 µm, gap 25 µm, claw finger 25 µm, claw gap 6 µm); away from it the estimate is first-order and is replaced as soon as a C-matrix of the actual design exists.

hanger_k is the voltage coupling coefficient k = (Z0e − Z0o)/(Z0e + Z0o) of the parallel-coupled section of a hanger coupler, per ground-strip width (µm), used for the external Q of a λ/4 hanger: Q_ext = π / (2 k² sin²(β l_c)) (Besedin & Menushenkov 2018). Calibrate it from a driven/eigenmode simulation.

Attributes

Functions

estimate(cell, quantity, params, pdk_name) → tuple[float | None, str]

(value fF, provenance) of quantity for a cell with params; (None, reason) if uncalibrated.

hanger_k(ground_gap_um) → float

Coupling coefficient for a hanger with the given ground strip (nearest calibrated width, e^-gap scaling).

hanger_kappa_MHz(f_GHz, vp_m_s, coupling_length_um, ...) → float

External linewidth κ/2π of a λ/4 hanger coupled over coupling_length_um near its shorted end.

invert(cell, quantity, value, pdk_name) → float | None

Knob value that gives value (fF) for quantity (LOM → layout).

Module Contents

quantcore_circuits.lom.calibration.estimate(cell: str, quantity: str, params: dict, pdk_name: str) → tuple[float | None, str]

(value fF, provenance) of quantity for a cell with params; (None, reason) if uncalibrated.

quantcore_circuits.lom.calibration.hanger_k(ground_gap_um: float) → float

Coupling coefficient for a hanger with the given ground strip (nearest calibrated width, e^-gap scaling).

quantcore_circuits.lom.calibration.hanger_kappa_MHz(f_GHz: float, vp_m_s: float, coupling_length_um: float, ground_gap_um: float) → float

External linewidth κ/2π of a λ/4 hanger coupled over coupling_length_um near its shorted end.

quantcore_circuits.lom.calibration.invert(cell: str, quantity: str, value: float, pdk_name: str) → float | None

Knob value that gives value (fF) for quantity (LOM → layout).

quantcore_circuits.lom.calibration.CALIBRATION: dict[tuple[str, str], dict]
quantcore_circuits.lom.calibration.HANGER_K
quantcore_circuits.lom.calibration.HANGER_K_REF = 'HFSS driven S21 notch fit, q1_r1_feedline R1, AEDT 2024 R1 (2026-11-03); was 0.06 (estimate)'